Display Units:
    Imperial Metric

    BCI Group Size

    27F

    Capacity @ C20

    100 Ah

    Reserve Capacity @ 25A

    185 minutes

    CCA

    965 Amps

    Dimensions

    12.09 x 6.65 x 9.33 inches

    Weight

    69.67 lbs.

    Electrical Specifications

    Nominal Voltage

    12-Volt

    Capacity @ C100

    110 Ah

    Capacity @ C20

    100 Ah

    Capacity @ C5

    81 Ah

    Reserve Capacity @ 25A

    185 minutes

    Reserve Capacity @ 75A

    40 minutes

    CCA

    965 Amps

    CA / MCA

    1170 Amps

    PHCA

    1950 Amps

    Internal Resistance

    2.5 mΩ

    Mechanical Specifications

    BCI Group Size

    27F

    Terminal Type

    DT

    Terminal Torque

    4.4 - 5.9

    53 - 71

    6 - 8

    Length

    12.09 inches

    Width

    6.65 inches

    Height (case only)

    8.43 inches

    Total Height (with terminals)

    9.33 inches

    Weight

    69.67 lbs.

    Case Type

    ABS Plastic

    Discharge Table

    Time Amps Rate
    20 hr 5.0 0.05 CA
    10 hr 9.1 0.10 CA
    8 hr 10.9 0.13 CA
    5 hr 17.2 0.20 CA
    3 hr 25.1 0.33 CA
    2 hr 34.0 0.50 CA
    1 hr 60.0 1.00 CA
    Condition Recommended Maximum Recommended Maximum
    Storage 5°F to 122°F -40°F to 160°F -15°C to 50°C -40°C to 71°C
    Operation 5°F to 104°F -40°F to 160°F -15°C to 40°C -40°C to 71°C
    Charge with TC 5°F to 122°F -40°F to 160°F -15°C to 50°C -40°C to 71°C
    Charge w/o TC 32°F to 104°F 5°F to 122°F 0°C to 40°C -15°C to 50°C
    *TC= Temperature Compensation
    Charge Stage 12V 24V 36V 48V
    Bulk 14.4 - 14.7V 28.8 - 29.4V 43.2 - 44.1V 57.6 - 58.8V
    Absorption 14.4 - 14.7V 28.8 - 29.4V 43.2 - 44.1V 57.6 - 58.8V
    Float 13.6V 27.2V 40.8V 54.6V
    TC Factor: (-2mV°F/cell) or (-4mV°C/cell)