FT1210

Full Throttle Series AGM Batteries

    Display Units:
    Imperial Metric

    BCI Group Size

    CG12

    Capacity @ C20

    140 Ah

    Reserve Capacity @ 25A

    321 minutes

    CCA

    1210 Amps

    Dimensions

    12.87 x 7.17 x 10.75 inches

    Weight

    98.1 lbs.

    Electrical Specifications

    Nominal Voltage

    12-Volt

    Capacity @ C100

    144 Ah

    Capacity @ C20

    140 Ah

    Capacity @ C5

    115 Ah

    Reserve Capacity @ 25A

    321 minutes

    Reserve Capacity @ 75A

    90 minutes

    Short Circuit Current

    3540 Amps

    CCA

    1210 Amps

    CA / MCA

    1505 Amps

    PHCA

    2400 Amps

    Internal Resistance

    3.5 mΩ

    Mechanical Specifications

    BCI Group Size

    CG12

    Terminal Type

    M8

    Terminal Torque

    5.2 - 6.7

    62 - 80

    7 - 9

    Length

    12.87 inches

    Width

    7.17 inches

    Height (case only)

    10.59 inches

    Total Height (with terminals)

    10.75 inches

    Weight

    98.1 lbs.

    Case Type

    ABS Plastic

    Discharge Table

    Time Amps Rate
    20 hr 7.0 0.05 CA
    10 hr 13.0 0.10 CA
    8 hr 14.8 0.13 CA
    5 hr 23.0 0.20 CA
    3 hr 32.2 0.33 CA
    2 hr 44.1 0.50 CA
    1 hr 80.0 1.00 CA
    Condition Recommended Maximum Recommended Maximum
    Storage 5°F to 122°F -40°F to 160°F -15°C to 50°C -40°C to 71°C
    Operation 5°F to 104°F -40°F to 160°F -15°C to 40°C -40°C to 71°C
    Charge with TC 5°F to 122°F -40°F to 160°F -15°C to 50°C -40°C to 71°C
    Charge w/o TC 32°F to 104°F 5°F to 122°F 0°C to 40°C -15°C to 50°C
    *TC= Temperature Compensation
    Charge Stage 12V 24V 36V 48V
    Bulk 14.4 - 14.7V 28.8 - 29.4V 43.2 - 44.1V 57.6 - 58.8V
    Absorption 14.4 - 14.7V 28.8 - 29.4V 43.2 - 44.1V 57.6 - 58.8V
    Float 13.6V 27.2V 40.8V 54.6V
    TC Factor: (-2mV°F/cell) or (-4mV°C/cell)