Display Units:
    Imperial Metric

    BCI Group Size

    B16CL-B

    Capacity @ C20

    18 Ah

    Reserve Capacity @ 25A

    26 minutes

    CCA

    265 Amps

    Dimensions

    x x inches

    Weight

    lbs.

    Electrical Specifications

    Nominal Voltage

    12-Volt

    Capacity @ C100

    20 Ah

    Capacity @ C20

    18 Ah

    Capacity @ C5

    15 Ah

    Reserve Capacity @ 25A

    26 minutes

    Reserve Capacity @ 75A

    5.3 minutes

    CCA

    265 Amps

    CA / MCA

    350 Amps

    PHCA

    625 Amps

    Internal Resistance

    7.0 mΩ

    Mechanical Specifications

    BCI Group Size

    B16CL-B

    Terminal Type

    M6

    Terminal Torque

    3.3 - 4.8

    40 - 57.5

    4.5 - 6.5

    Weight

    lbs.

    Case Type

    ABS Plastic

    Discharge Table

    Time Amps Rate
    20 hr 0.9 0.05 CA
    10 hr 1.8 0.10 CA
    8 hr 2.0 0.13 CA
    5 hr 3.0 0.20 CA
    3 hr 4.6 0.33 CA
    2 hr 6.9 0.50 CA
    1 hr 12.9 1.00 CA
    Condition Recommended Maximum Recommended Maximum
    Storage 5°F to 122°F -40°F to 160°F -15°C to 50°C -40°C to 71°C
    Operation 5°F to 104°F -40°F to 160°F -15°C to 40°C -40°C to 71°C
    Charge with TC 5°F to 122°F -40°F to 160°F -15°C to 50°C -40°C to 71°C
    Charge w/o TC 32°F to 104°F 5°F to 122°F 0°C to 40°C -15°C to 50°C
    *TC= Temperature Compensation
    Charge Stage 12V 24V 36V 48V
    Bulk 14.4 - 14.7V 28.8 - 29.4V 43.2 - 44.1V 57.6 - 58.8V
    Absorption 14.4 - 14.7V 28.8 - 29.4V 43.2 - 44.1V 57.6 - 58.8V
    Float 13.6V 27.2V 40.8V 54.6V
    TC Factor: (-2mV°F/cell) or (-4mV°C/cell)